Kyocera TASKalfa 7002i Service Manual page 777

Hide thumbs Also See for TASKalfa 7002i:
Table of Contents

Advertisement

Setting: G
1.Select the item to set.
2.By using [Left/Right cursor] keys or the numeric keys, enter the values which are shown on the
back page of the adjustment original.
Items
L
L parameter setting
a
A value setting
b
B value setting
3.Press the [Start] key to set the setting value.
Setting: B
1.Select the item to set.
2.By using [Left/Right cursor] keys or the numeric keys, enter the values which are shown on the
back page of the adjustment original.
Items
L
L parameter setting
a
A value setting
b
B value setting
3.Press the [Start] key to set the setting value.
Setting: Adjust Original
* :This setting is usually unnecessary.
Items
Lead
Set the adjustment value of the
leading edge.
Main Scan
Sets the adjustment value of the
left edge.
Sub Scan
Set the adjustment value of the
trailing edge.
*1: Centimeter specification, *2: inch specification
1.Measure the distances "A", "B" and "C" from the upper edge of black belt 1 to the lower edge of
black belt 3 of the adjustment original.
Measurement procedure
1) Measure the distance "A", "B" and "C" between two points as follows. (A: 30mm from the
left edge, B: 105mm from the left edge, C: 180mm from the left edge)
Measure the distance from the leading edge to the top edge of black belt 1.
2) Apply the following formula for the values obtained: ((A+B+C)/3)
2.Enter the value solved in "Lead" using the the [+] [-] keys keys.
3.Press the [Start] key to set the setting value.
4.Measure the distance "F" from the left edge to the right edge of black belt 2 on the adjustment
original.
Measurement procedure
Contents
Contents
Contents
6-184
Setting range
Data
variation
0.0 to 100
-200 to 200
-200 to 200
Setting range
Data
variation
0.0 to 100
-200 to 200
-200 to 200
Setting range
Data
variation
4.0 to 6.0
0.1mm
0.16 to 0.24
0.01 inch
9.0 to 11.0
0.1mm
0.36 to 0.44
0.01 inch
189.0 to 191.0
0.1mm
7.44 to 7.52
0.01 inch
2WA/2NJ/2RK
Initial
setting
-
67.8
-
-51.3
-
48.9
Initial
setting
-
38.8
-
25.3
-
-22.8
Initial
setting
5.0 *1
0.2 *2
10.0 *1
0.4 *2
190.0 *1
7.49 *2

Hide quick links: