(4)Press the [Stop] key.
5. Adjusting the halftone automatically (maintenance mode U410)
(1)Input "410" using the numeric keys.
(2)Press the [Start] key.
*: Execution information screen is displayed.
*: Test patterns 1 and 2 are output on the A4 paper.
(3)Set the output test pattern 1 as original, in the back side which the direction of the arrow is, looking down
the side which is printing to the original glass.
*: Set test pattern 1 and place approximately 20 sheets of white paper on it.
(4)Press the [Start] key.
*: The 1st auto adjustment is executed.
(5)Set the output Test Pattern 2 as the original.
*: Set test pattern 2 and place approximately 20 sheets of white paper on it.
(6)Press the [Start] key.
*: The 2nd auto adjustment is executed.
(7)[Finish] displays after normal completion.
6. Resetting the setting values
Check and enter the setting values from Maintenance Report printed beforehand.
U251: cassette counter
U265: OEM purchaser code
U065: Main Scan adjustment
U402: Print margin adjustment
Setting data modified at setup
Re-registering the certificate (network).
In case of custom setting on the operation panel: U224: re-register Home screen
If "Interface Block setting" or "Security Level" were changed in system menu, reset them.
If Security Kit is installed, enter the encrypted code that was initially set.
Reconfigure the network since the MAC address (Printer name) is changed, according to the environment
setting.
7. Exiting from the maintenance mode
Input "001" using the numeric keys and press the [Start] key.
Figure 4-268
4-183
2WA/2NJ/2RK