U252
Destination
(Message: Set Destination)
Contents
Switch the operations and screens of the main unit according to the destination.
Purpose
Execute after initializing the backup RAM, in order to return the setting to the value before
replacement or initialization
Method
1.Press the [Start] key.
2.Select the item to set.
Items
Japan Metric *1
Inch *2
Europe Metric *2
Asia Pacific *2
Australia *2
China *2
Korea *2
*1: 100 V model only, *2: Except 100 V model
* :Initial setting: Destination
3.Press the [Start] key.
* :Initializes according to the destination
4.Turn the power switch off then on. Wait more than 5 seconds between the power off and on.
* :An error code is displayed when an error occurs.
When errors occur, turn the power switch off then on, and execute initialization using mainte-
nance mode U252.
Error codes
Items
0001
0002
0020
0040
Japan metric specification
Inch specification
Europe Metric specification
Asia Pacific specification
Australia specification
China specification
Korea specification
Controller (Entity Error)
Controller error
Engine error
Scanner error