U193
Fuser drive control setting
(Message: Set Fuser Drive Control)
Contents
Change the fuser drive control setting
Purpose
Set the fuser drive control after completing the print as the fuser trace measure.
Setting
1.Press the [Start] key.
2.Select the [Bias].
3.Change the setting value by using [+] [-] key or the numeric keypad.
Items
B/W
Half
4.Press the [Start] key and then fix the setting.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
U198
Fuser phase control setting
(Message: Set Fuser Phase Control)
Contents
Change the fuser phase control.
Purpose
Use the fuser phase control change.
Setting
1.Press the [Start] key.
2.Change the setting value by using [+] [-] key or the numeric keypad.
Items
Mode
3.Press the [Start] key and then fix the setting.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Contents
Monochrome (High speed)
Half speed
Contents
Fuser phase control type setting
6-108
2WA/2NJ/2RK
Setting range
Initial setting
0 to 200
0 to 200
Setting range
Initial setting
0 to 1
0
50
50