U052
Fuser motor control setting
(Message: Set Fuser Motor Speed)
Contents
Correct the input of the sensor data which is described in the bundled sheet at exchanging a loop
sensor and fuser motor.
Purpose
Execute to exchange the loop sensor or the conveying unit.
Execution
1.Press the [Start] key.
2.Select the item to execute.
* :The screen for executing is displayed.
Items
Set Loop Sensor
Loop Sensor Control
Set Loop Sensor Valid Set if the loop sensor is or not.
Chk Loop Sensor
Execution: Set Loop Sensor
1.Select [Scanning Board1].
2.Press [+] [-] key and then input the sensor data value of bundled
sheet DATA1.
3.Select [Scanning Board2].
4.Press [+] [-] key and then input the sensor data value of bundled
sheet DATA2.
Items
Scanning
Setting of Scanning Board1
Board1
Scanning
Setting of Scanning Board2
Board2
5.Press the [Start] key and then fix the setting value.
Input of the loop sensor data value
Setting of the loop sensor detection control
Displays the loop sensor value.
Contents
6-46
Contents
How to read the sensor
data value
1
2
3
4
5
6
7
8
9
10
Setting
Data
range
variation
150 to 250
0.01V
130 to 230
0.01V
2WA/2NJ/2RK
3
6
4
Initial
setting
0