Kyocera TASKalfa 7002i Service Manual page 640

Hide thumbs Also See for TASKalfa 7002i:
Table of Contents

Advertisement

Execution: Loop Sensor Control
1.Select the setting contents.
2.Select [On] or [Off].
Dis-
play
No.1
Sensor detection ON/OFF setting at 125 to 250 mm position than the
paper leading end
No.2
Sensor detection ON/OFF setting at 250 to 290mm position than the
paper leading end
No.3
Sensor detection ON/OFF setting at 300 to 330mm position than the
paper leading end
No.4
Sensor detection ON/OFF setting at 350 to 370mm position than the
paper leading end
No.5
Sensor detection ON/OFF setting at 400 to 410mm position than the
paper leading end
No.6
Sensor detection ON/OFF setting at 450mm position than the paper
leading end
3.Press the [Start] key and then fix the setting value.
Execution: Set Loop Sensor Valid
1.Select [On] or [Off].
Display
Loop Sensor Valid
2.Press the [Start] key and then fix the setting value.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Description
Description
Set if the loop sensor is or not.
6-47
2WA/2NJ/2RK
Initial setting
1 (On)
1 (On)
1 (On)
1 (On)
0 (Off)
0 (Off)
Initial setting
1 (On)