Table 5-4 Frequency Allowable Range And Preset Value; Table 5-5 Band And Frequency Allowable Range - Agilent Technologies N9360A Programming Manual

Multi ue tester
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

N9360A Multi UE Tester W-CDMA Programming Manual
Frequency
TESTs:MANual:RFCH:FREQuency <real>
TESTs:MANual:RFCH:FREQuency?
This command sets the frequency and can be used in Stand-by
or Connection status.
When RFCH is set in the Connection status, handover will
starts. (However, if the value of RFCH is set to the same value as
the one currently set, handover will not start.)
The allowable range and preset values are as follows:

Table 5-4 Frequency Allowable Range and Preset Value

Band
Allowable Range [Hz]
1
1920000000 to 1980000000 in 2000 step
6
830000000 to 84000000 in 2000 step
832500000, 837500000
This query command returns the set frequency of RFCH with
real. The range of the value is same as that of the command
parameter.
TESTs:MANual:RFCH:FREQuency <int 1>, <real 2>
TESTs:MANual:RFCH:FREQuency?
This command sets a Band and frequency for RF (uplink) in
Stand-by or Connection status.
When RFCH is set in the Connection status, handover will
starts. (However, if the value of RFCH is set to the same value as
the one currently set, handover will not start.)
is a Band and set to 1 at preset.
<int 1>
(uplink frequency) and set to
allowable ranges are as follows:

Table 5-5 Band and Frequency Allowable Range

Band
Allowable Range
1
1920000000 to 1980000000 in 2000 step
6
830000000 to 84000000 in 2000 step
832500000, 837500000
Programming Command Reference
Preset Value
1922400000
832400000
is a frequency
<int 2>
at preset. The
1922400000
5
5-51

Advertisement

Table of Contents
loading

Table of Contents