N9360A Multi UE Tester W-CDMA Programming Manual
BS Call
TESTs:MANual:BSCall
This command executes a call setup to the mobile phone from
the Tester.
BS Release
TESTs:MANual:BSRelease
This command releases the call from the Tester.
MS Answer
TESTs:MANual:MSAnswer
This command starts the connection by manual response during
response time after MS Call initiation.
Signaling State
TESTs:MANual:SIGNaling:STATe?
This query command returns the test step currently executed
for a test cycle. The return value contains the status in
execution of 7 bits as follows.
bit 0(1): MS Call/ BS Call
bit 1(2): Talk, RF Test
bit 2(4): MS Release/BS Release
bit 3(8): Time out error; currently unused
bit 4(16): End; Stand-by status
bit 5(32): Location Update
bit 6(64): Busy
bit7(128): Currently unused
bit8(256): SMS-MO
bit9(512): SMS-MT
Programming Command Reference