Agilent Technologies N9360A Programming Manual page 112

Multi ue tester
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

5
Programming Command Reference
5-66
At start up of the Tester, the queries in <int 1> and <int 2>
format are returned.
If the setting with <int> format is performed, the format of the
query changes to <int> format.
If the setting with <int 1> and <int 2> format is performed,
the format of the query returns to <int 1> and <int 2>
format.
This query command returns the set Band and Frequency of
RFCH with real. The range of the value is same as that of the
command parameter.
Amplitude
TXANalyzer:AMPLitude <real>
TXANalyzer:AMPLitude?
This command sets the amplitude of output signal from the
Tester applied to the mobile phone under test in each Band. The
allowable range is from
preset, this is set to
-50.0
This query command returns the set amplitude of output signal
by real ranging from
-110.0
Modulation
TXANalyzer:MODulation <<
IDLE|IDLE+DPCH(PN9)|IDLE+DPCH(PN15)| <<
IDLE+DPCH(PN9)+OCNS|IDLE+DPCH(PN15)+OCNS
TXANalyzer:MODulation?
This command defines a type of modulation. The parameter is
,
IDLE
IDLE+DPCH(PN9)
IDLE+DPCH(PN9)+OCNS
this is set to
. This works with Modulation on the [Signal
IDLE
Generator] screen.
: Outputs CPICH, P-CCPCH, SCH, PICH and S-CCPCH.
IDLE
: Outputs
IDLE+DPCH(PN9)
12.2kbps (PN9).
: Outputs
IDLE+DPCH(PN15)
12.2kbps(PN15).
N9360A Multi UE Tester W-CDMA Programming Manual
to
(dBm) in
-110.0
-20.0
(dBm).
to
(dBm).
-20.0
,
,
IDLE+DPCH(PN15)
, or
IDLE+DPCH(PN15)+OCNS
(without S-CCPCH) and RMC
IDLE
(without S-CCPCH) and RMC
IDLE
steps. At
0.1
. At preset,

Advertisement