Table 5-11 Frequency Allowable Range And Preset Value; Table 5-12 Band And Frequency Allowable Range - Agilent Technologies N9360A Programming Manual

Multi ue tester
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

N9360A Multi UE Tester W-CDMA Programming Manual
If the setting with <int 1> and <int 2> format is performed,
the format of the query returns to <int 1> and <int 2>
format.
This query command returns the set Band and Channel number
of RFCH with integer. The range of the value is same as that of
the command parameter.
Frequency
TXANalyzer:RFCH:FREQuency <real>
TXANalyzer:RFCH:FREQuency?
This command sets the frequency. The allowable range and
preset values are as follows:

Table 5-11 Frequency Allowable Range and Preset Value

Band
Allowable Range [Hz]
1
1920000000 to 1980000000 in 2000 step
6
830000000 to 840000000 in 2000 step,
832500000, 837500000
This query command returns the set frequency of the RFCH
with real. The range of the value is same as that of the command
parameter.
TXANalyzer:RFCH:FREQuency <int 1>,<real 2>
TXANalyzer:RFCH:FREQuency?
This command specifies a Band and frequency for RF (uplink)
on Stand-by screen.
<int 1> is a Band and set to
frequency (uplink frequency) and set to
The allowable ranges are as follows:

Table 5-12 Band and Frequency Allowable range

Band
Allowable Range [Hz]
1
1920000000 to 1980000000 in 2000 step
6
830000000 to 840000000 in 2000 step, 832500000, 837500000
Programming Command Reference
at preset. <int 2> is a
1
1922400000
5
Preset Value
1922400000
4162
at preset.
5-65

Advertisement

Table of Contents
loading

Table of Contents