Table 5-14 Band And Rfch Allowable Range; Table 5-15 Frequency Allowable Range And Preset Value - Agilent Technologies N9360A Programming Manual

Multi ue tester
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

N9360A Multi UE Tester W-CDMA Programming Manual
RFGenerator:CHANnel?
This command sets a Band and channel for RF (downlink) on
the [Stand-by] screen.
<int 1> is a Band and set to 1 at preset. <int 2> is a variable
(uplink channel number) and set to
allowable ranges are as follows:

Table 5-14 Band and RFCH Allowable Range

Band
Allowable Range
1
10550 to 10850
6
4375 to 4425, 1037, 1062
At start up of the Tester, the queries in <int 1> and <int 2>
format are returned.
If the setting with <int> format is performed, the format of the
query changes to <int> format.
If the setting with <int 1> and <int 2> format is performed,
the format of the query returns to <int 1> and <int 2>
format.
This query command returns the set Band and Channel number
of RFCH with integer. The range of the value is same as that of
the command parameter.
Frequency
RFGenerator:FREQuency <real>
RFGenerator:FREQuency?
This command sets the frequency. The allowable range and preset
values are as follows:

Table 5-15 Frequency Allowable Range and Preset Value

Band
Allowable Range [Hz]
1
2110000000 to 2170000000 in 2000 steps
6
875000000 to 885000000 in 2000 steps,
877500000, 882500000
Programming Command Reference
at preset. The
10562
Preset Value [Hz]
2112400000
877400000
5
5-73