Manual Test Function - Agilent Technologies N9360A Programming Manual

Multi ue tester
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

7
Sample Program
Table 7-4 Program Comments
Row
Description
54:
Queries the measurement result of Open Loop TX Power.
55:
Displays the measurement value and judgment result of Open Loop TX Power in the status field.
56:
Queries the measurement result of ILP (Down Min)
57:
Displays the measurement value and judgment result of ILP(Down Min) in the status field.
58:
Queries the measurement result of ILP (Down Max)
59:
Displays the measurement value and judgment result of ILP(Down Max) in the status field.
60:
Queries the measurement result of ILP (Up Min)
61:
Displays the measurement value and judgment result of ILP(Up Min) in the status field.
62:
Queries the measurement result of ILP (Up Max)
63:
Displays the measurement value and judgment result of ILP(Up Max) in the status field.
64:
Queries the measurement result of ILP (10 Slots Down)
65:
Displays the measurement value and judgment result of ILP(10 Slots Down) in the status field.
66:
Queries the measurement result of ILP (10 Slots Up)
67:
Displays the measurement value and judgment result of ILP (10 Slots Up) in the status field.
68:
Queries the measurement result MAX TX Power.
69:
Displays the measurement value and judgment result of MAX TX Power in the status field.
70:
Queries the measurement result of Frequency Error.
71:
Displays the measurement value and judgment result of Frequency Error in the status field.
72:
Queries the measurement result of EVM.
73:
Displays the measurement value and judgment result of EVM in the status field.
74:
Queries the measurement result of Sensitivity/BER.
75:
Displays the measurement value and judgment result of Sensitivity/BER in the status field.
78:
Displays Complete message in the status field.

Manual Test Function

7-10
The Tester is configured to the required setting for the test at
the beginning of this function. Then, the Tester executes the TX
Power, Frequency Error, EVM and BER measurement.
the PASS/FAIL test result and measurement results are shown
on the status field. Operations by an operator for the test are
shown on the status field.