Agilent Technologies N9360A Programming Manual page 92

Multi ue tester
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

5
Programming Command Reference
5-46
Inner Loop Power Measurement (10 Slots Down)
TESTs:AUTO:RESults:INNErpower1:10SlotsDown?
TESTs:AUTO:RESults:INNErpower2:10SlotsDown?
TESTs:AUTO:RESults:INNErpower3:10SlotsDown?
TESTs:AUTO:RESults:INNErpower4:10SlotsDown?
TESTs:AUTO:RESults:INNErpower5:10SlotsDown?
TESTs:AUTO:RESults:INNErpower6:10SlotsDown?
This query command returns the measurement result values,
,
and
<int 1>
<int 2>
(1 digit) is
<int 1>
measurement range, or
range or Inner Loop Power 10 Slots Down is not measured.
(1 digit) is the test result for the pass (0) or fail (1).
<int 2>
(up to 6 letters) is the measured data ranging from
<real 3>
to
-99.99
+99.99
range or Inner Loop Power 10 Slots Down in not measured,
the value
is returned.
-99.99
Inner Loop Power Measurement (10 Slots Up)
TESTs:AUTO:RESults:INNErpower1:10SlotsUp?
TESTs:AUTO:RESults:INNErpower2:10SlotsUp?
TESTs:AUTO:RESults:INNErpower3:10SlotsUp?
TESTs:AUTO:RESults:INNErpower4:10SlotsUp?
TESTs:AUTO:RESults:INNErpower5:10SlotsUp?
TESTs:AUTO:RESults:INNErpower6:10SlotsUp?
This query command returns the Inner Loop Power 10 Slots Up
measurement result values,
for each channel.
(1 digit) is
<int 1>
measurement range, or
range or Inner Loop Power 10 Slots Down is not measured.
(1 digit) is the test result for the pass (0) or fail (1).
<int 2>
N9360A Multi UE Tester W-CDMA Programming Manual
, for each channel.
<real 3>
if measurement result is within the
0
if measurement result is out of
1
in dB. If measurement result is out of
,
<int 1>
<int 2>
if measurement result is within the
0
if measurement result is out of
1
and
,
<real 3>

Advertisement