5
Programming Command Reference
5-34
This command sets the high limit for the test in each band set by
the
Band
command described on
is from
to
-99.99
0.00
to
(dB). This command is valid only when the W07
-30.00
option is installed in the Tester. If the W07 option is not
installed in the Tester, an execution error occurs.
This query command returns the set high limit of the test with
real. The range of the value is same as that of the command
parameter.
ACLR DSB 10MHz
CONFigure:CONDition:LIMit:ACLR10mhz <real HI>
CONFigure:CONDition:LIMit:ACLR10mhz?
This command sets the high limit for the test in each band set by
the
Band
command described on
is from
to
-99.99
0.00
to
(dB). This command is valid only when the W07
-40.00
option is installed in the Tester. If the W07 option is not
installed in the Tester, an execution error occurs.
This query command returns the set high limit of the test with
real. The range of the value is same as that of the command
parameter.
OBW
CONFigure:CONDition:LIMit:OBW <real HI>
CONFigure:CONDition:LIMit:OBW?
This command sets the high limit for OBW Test in each band set
by the
Band
command described on
range is from
to
0.00
is set to
(MHz). This command is valid only when the W07
5.00
option is installed in the Tester. If the W07 option is not
installed in the Tester, an execution error occurs.
This query command returns the set high limit of OBW Test
with real. The range of the value is same as that of the command
parameter.
N9360A Multi UE Tester W-CDMA Programming Manual
page
28. The allowable range
(dB) in
steps. At preset, this is set
0.01
page
28. The allowable range
(dB) in
steps. At preset, this is set
0.01
page
28. The allowable
(MHz) in
steps. At preset, this
9.99
0.01

Advertisement