Table 6-11 Command Cross Reference for [Stand-by] Screen
Item
BER
CPICH RSCP

Measuring Screens

Table 6-12 Command Cross Reference for [Measuring] Screen

Item
Power Control Level
Location Update
BS Call
BS Release
MS Answer
Signaling State
Call Clear Status
Signaling Results
CPICH RSCP

Test Result

Table 6-13 Command Cross Reference for Manual Test Result

Item
PRACH Power Measurement
TX Power Measurement
Frequency Error Measurement
EVM Measurement
N9360A Multi UE Tester W-CDMA Programming Manual
Command
TEST:MAN:BER:STAT ON|OFF|1|0
TEST:MAN:BER:STAT?
TEST:MAN:CPRS:STAT ON|OFF|1|0
TEST:MAN:CPRS:STAT?
The following commands are used to set the controls and
parameters associated with the [Measuring] screen.
Command
TEST:MAN:PLEV UP|DOWN|CONTUP|CONTDOWN|HOLD <int>
TEST:MAN:PLEV?
TEST:MAN:LOC
TEST:MAN:BSC
TEST:MAN:BSR
TEST:MAN:MSA
TEST:MAN:SIGN:STAT?
TEST:MAN:SCL
TEST:MAN:RES:SIGN?
TEST:MAN:CPRS:MEAS
The following query commands return a set of result values of
the Manual Test. There is no command form of this command.
Command
TEST:MAN:RES:PRACH?
TEST:MAN:RES:TXP?
TEST:MAN:RES:FREQ?
TEST:MAN:RES:EVM?