Table 7-4 Program Comments - Agilent Technologies N9360A Programming Manual

Multi ue tester
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

Table 7-4 Program Comments

Row
Description
2:
Declares the variables to store test results.
4:
Erases the status field.
7:
Queries the manufacturer, model number, serial number and revision number of the firmware.
8-11:
Displays the manufacturer, model number, serial number and revision number of the firmware in the status
field.
14:
Resets the Tester to the default setting for programming.
15:
Activates the Loss correction function.
16:
Sets the Loss RF IN field.
17:
Sets the Loss RF OUT field.
18:
Sets the 3GPP System.
19:
Sets the Band and RFCH.
20:
Sets the Band and RFCH.
23:
Selects the measurement value screen.
26:
Starts the Automatic Test.
27:
Directs a user: Turn on the mobile phone.
28:
Waits until the location update is completed.
29:
Directs the user: Please MS Call.
30:
Waits until the state is Talk test.
31:
Directs the user: Talk.
32-36:
Confirms PASS/FAIL of the voice loop-back test.
Displays the test results, input to the Tester from the PC by the user, on the screen of the Tester.
37:
Directs the user: Please MS Release.
38:
Waits until the MS Release is completed.
39:
Directs the user: Please off hook.
40:
Waits until the state is Talk test.
41:
Directs the user: Talk.
42-46:
Confirms PASS/FAIL of the voice loop-back test.
Displays the test results, input to the Tester from the PC by the user, on the screen of the Tester.
48:
Waits until the measurement is completed.
51:
Defines the variable of channel number for the measurement result display.
52: (-76:)
For channel = 1 to 1.