Preparation In The Machine Tanks; Order Numbers (Abc Codes) For Msc/D-Lab Chemicals; Mixing Tank Solutions With Msc/D-Lab Chemicals - AGFA d-lab.3 Technical Documentation Manual

Digital compact lab
Table of Contents

Advertisement

Chemicals

Preparation in the Machine Tanks

Open the Paper Processor cover.
Fill the replenisher tank until the lower level
sensors are covered to avoid the request for
the Easy Paper Box connection.
Fill all machine tanks with hot water and let the
machine run for a short while:
-to rinse the circulation system
-to remove any chemical residues
Switch off the machine, completely drain the
cleaning water and make sure that all drain
cocks are closed correctly.
Check the hose positioning:
No leakage, sharp bends and squeezing.
There are no air bubbles allowed in the hose
system (self-learning pump system).
Empty the replenisher tanks only after the
machine has started up with chemicals,
otherwise the request to connect an Easy
Paper Box comes too soon.

Order Numbers (ABC Codes) for MSC/d-lab Chemicals

The use of the AGFA MSC/d-lab CHEMICALS,
offered by Agfa as well as of the AGFACOLOR
PRESTIGE DIGITAL paper is mandatory.
MSC/d-lab tank CD for 2x 18.5 liters:
contains concentrate for two CD tank fillings
MSC/d-lab tank BX for 2x 18 liters:
contains concentrate for two BX tank fillings
MSC/d-lab tank SB for 2x 11-12.5 liters:
contains concentrate for three SB tank fillings

Mixing Tank Solutions with MSC/d-lab Chemicals

To make sure that no chemicals splashes on the
machine, fasten the plastic covers from the
accessory pack on the machine.
3.2
2003-06-01 /PN 9008
5HX5G
5HX7L
5HX8N
Operation
AGFA d-lab.3