Daily Calibration Without Mbl Concept (Exception); Calibration Of New Paper, Emulsion Changes, Or Correction Of A Paper Channel (Not Master Paper) - AGFA d-lab.3 Technical Documentation Manual

Digital compact lab
Table of Contents

Advertisement

Operation

Daily calibration without MBL concept (exception)

For the respective paper that is needed a PBL is
printed or repeated, if necessary. This can always
be a PBL without new laser point calibration (with
the exception of the first time).
When is this exception required or possible?
− When using paper types at the same time
which are quite different, e.g. papers of
different manufacturers. In this case the MBL
corrections cannot show exactly the same
effect for all papers.
− Only one paper channel is used (or only very
few). The more paper channels the more work.
− If the Main conditions (see previous page) for
working with the MBL cannot be met.
Calibration of new paper, emulsion changes, or correction of a paper channel
(not master paper)
1. Print an MBL
This provides for a calibrated condition of the
machine.
2. Print the PBL right after the MBL:
− with laser point for new papers other than
the master paper,
or
− PBL without laser point in case of emulsion
changes.
AGFA d-lab.3
2003-06-01 /PN 9008
Tests
5.5