Production
Slide Print
Slide filters already inserted.
Order configurations already created for slide
prints. Combiprints are possible.
In this print mode the preview function is always
used.
Do not scan several slides in row without starting
a print, but: Scan slides, edit, print, scan next
slide, and so on.
– Put in the slide carrier
The automatic pixel correction is performed. Do
not withdraw the slide carrier during this
procedure!
– Call up:
Print mode
Slide print
The top part of the carrier moves out.
– If required, select a different slide print
configuration
– Touch Change configuration if necessary to
change the configuration for the whole order.
– Put in the slide correctly and push in the top
part of the carrier.
− The slide is scanned (Prescan and Main
Scan) and shown on the screen.
− Then the top part of the carrier is moved
out again.
6.50
2003-06-01 /PN 9008
Operation
dlab2603
dlab2602
AGFA d-lab.3