AGFA d-lab.3 Technical Documentation Manual page 41

Digital compact lab
Table of Contents

Advertisement

Operation
− Perform the daily maintenance jobs (see also
Daily maintenance, Register 8).
− Reply to all checks, if any:
− In case of unfinished APS orders: For
unfinished APS orders, answer the query
whether they should be saved. Orders that
are not saved are lost.
− In case of orders that are not priced confirm
the warning messages. The orders are
saved in any case.
The d-lab is shut down and switched off.
Caution!
Do not switch the d-lab on and off manually,
always use the timer.
Do not switch off the main breaker (1) !
Switching off the machine by the main breaker will
considerably reduce the service life of the laser as
the fan of the laser is switched off as well and the
cooling required for the laser is no longer possible!
If the machine was switched off via the main
breaker wait at least one minute before you switch
on again. Otherwise the hard disk could be
damaged.