Setting The Travel And The Operation Speed - Mitsubishi FX2N-10GM Hardware / Programming Manual

Melsec-f
Hide thumbs Also See for FX2N-10GM:
Table of Contents

Advertisement

FX Series Positioning Controllers
7.3.4

Setting the travel and the operation speed

Set the positioning data such as the travel and operation speed from the programmable controller.
Buffer memory No.
#100 to #1999:FX
#100 to #6999:FX
These buffer memories are always handled as 32-bit data.
Refer to the positioning program example shown below.
Program example
Write the set values in the D51, the D50 and the D100 to the BFM.
Drive
input
FNC79
Drive
input
FNC79
By turning ON special auxiliary relay M9014 (BFM #20, b14), 32-bit buffer memories are
treated as separate 16-bit types. This allows the TO instruction (without D ) to send 16-bit
data to each BFM separately. (Refer to Section 7.2.1.)
Positioning program example
In the positioning program, the travel, the operation speed, etc. are specified indirectly (Refer
to Section 5.5.).
Only travel and speed are shown in this example. In addition, all the devices such as the
radius, the center point, etc. that can be specified indirectly can be set from the programmable
controller.
cod00(DRV)
x DD100;
cod00(DRV)
x D0;
Data change timing
The data can be written to the buffer memories without regard to the mode (AUTO or MANU)
or the status (BUSY or READY) of the positioning unit. However, because the positioning unit
reads the travel and the speed set when the program is executed (when the cod instruction is
executed in the example above), the set data must be written to the buffer memories before the
instruction is executed. The data written while or after the instruction is executed becomes
valid when the instruction is executed next time.
-10GM
2N
-20GM
2N
K 0
K100
[D]TO
Special
BFM
Programmable
unit No.0
controller
transfer source
K 0
K200
TO
The travel is specified by D101 and D100 (32-bit data). ("DD"
specifies 32 bits.) The speed is specified as "fDDOOO".
Data register No.
The travel is specified by D0 (16-bit data). The speed is
specified as fDOOO.
Data register No.
Communication with Programmable Controller 7
Programmable
D50
K1
controller
D51, D50
Number of
transgers
Programmable
D100
K1
controller
D100
Positioning unit
No.0 BFM #101,
#100(D101, D100)
Positioning unit
No.0 BFM
#200(D200)
Data register No.
7-9