Mitsubishi FX2N-10GM Hardware / Programming Manual page 78

Melsec-f
Hide thumbs Also See for FX2N-10GM:
Table of Contents

Advertisement

FX Series Positioning Controllers
With some exceptions, each parameter is assigned a special data register (special D).
When parameters are set from the panel of a peripheral unit, the same data is simultaneously
set in the special Ds.
The data in the special Ds can be changed using the positioning program during operation.
Operation is then performed in accordance with the changed data.
However, when power is turned ON, the special Ds are initialized with the held data in the
parameter memories.
This also happens when the mode is changed over from MANU to AUTO.
→ Continued on the next page.When a value beyond the allowed range of a parameter is
entered, the positioning unit performs the following operation.
• Parameter written using a peripheral unit
A parameter set error (Error code: 2000 to 2056) occurs, and the positioning unit stops.
When this error occurs, the ERROR-x and/or ERROR-y LEDs provided on the panel of the
positioning unit are lit.
A correct value must be written to the parameter to reset the error status.
• Parameter written using a positioning program
Though the positioning unit does not stop, the parameter is set to the following value.
When the entered value is larger than the effective range:
A parameter related to time or speed is set to the maximum value.
When the entered value is smaller than the effective range:
A parameter related to time or speed is set to the minimum value.
Parameters 4
4-2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx2n-20gm

Table of Contents