Cod 76 (Canc): Compensation Cancel - Mitsubishi FX2N-10GM Hardware / Programming Manual

Melsec-f
Hide thumbs Also See for FX2N-10GM:
Table of Contents

Advertisement

FX Series Positioning Controllers
5.6.14

cod 76 (CANC): Compensation cancel

cod 76
CANC
FX
Basic
format
c CANC
The compensations cod73 to cod75 above are canceled.
Program example
cod91 (INC); Specifies the incremental travel method.
cod00 (DRV) Moves the machine to Point A.
x1000;
cod73 (MOVC) Compensates the travel.
x10; Sets the X axis compensation value to "10".
cod00 (DRV) Moves the machine to Point B.
x1500;
cod76 (CANC) Cancels compensation.
Acceleration is determined by PARA. 8 and PARA. 9.
The operation speed is determined by PARA. 4 (maximum speed).
Travel compensation/Center point compensation/
Radius compensation/Compensation cancel
Servo end check
No
Instruction group
-10GM
2N
cod 76
CANC
Remarks
C
Compensation cancel
Program format 5
Applicable models
Series name
FX
-10GM
2N
FX
-20GM
2N
FX
-20GM
2N
cod 76
CANC
5-37
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx2n-20gm

Table of Contents