FX Series Positioning Controllers
1.

Introduction

1.1

Introduction Procedure and Reference Manuals

Introduction procedure
Purchase of product
Confirmation of accessories
x
After purchasing the
product, make sure at first
that all accessories are
packed together.
Confirmation of product
x
Connect the power supply,
and make sure based on the
LED lighting status that the
product is normally
operating.
x
Perform JOG+ and JOG-
operations using a
peripheral unit (such as E-
20TP), and make sure
pulses are normally output.
Installation and wiring
x
Install and wire the product.
x
After finishing wiring, check
it.
At this time, you can check
the wiring between the
positioning unit and the
motor amplifier by
performing JOG operation
(from a connected input or
peripheral unit).
Loading of program
Load a positioning program
from a peripheral unit, and
adjust the operation.
The FX
-10GM/20GM is packed together with the following accessories.
2N
x
Power cable
FX
-100MPCB
1 cable
2N
FX
-100BPCB (only in FX
2N
x
PC connection cable
FX
-GM-5EC
1 cable
2N
LED lighting status
POWER LED: Lit
READY-x LED: Lit
READY-y LED: Lit
Other LEDs: Extinguished
During JOG+ ON
The READY (READY-x or READY-y) LED for the specified axis is
extinguished,
and the FP LED is flashing at a high speed (so looks like being lit).
During JOG-ON
The READY (READY-x or READY-y) LED for the specified axis is
extinguished,
and the RP LED is flashing at a high speed (so looks like being lit).
For operating procedures of peripheral units, refer to corresponding operation
manuals.
Correctly perform wiring in accordance with "3. Wiring" in this manual.
For an operation which may cause danger, perform wiring so that the unit
conservatively operates when the power is shut down.
Set interlock to positions which should not be driven at the same time.
x
For creation of programs and description on instructions, refer to "5.
Expression in Program" in this manual.
x
For operating procedures of peripheral units, refer to corresponding
operation manuals.
x
If an error occurs, refer to "10. Troubleshooting" in this manual.