FX Series Positioning Controllers
PARA. 56: General purpose input declaration for FWD/RVS/ZRN
The dedicated inputs FWD (forward rotation JOG), RVS (reverse rotation JOG) or ZRN (zero
return) can be used as general purpose inputs.
When X372 to X377 (X375 to X377 in the FX
the parameters or the programs, this parameter must be set properly.
Table 4.52: General purpose input declaration for FWD/RVS/ZRN
Setting
Use X372 to X377 as
general purpose input
0
1
2
3
4
The table below shows the details of the special auxiliary relays.
(Those for the X axis only are available in the FX
Table 4.53: Special auxiliary relays
Details of command
Machine zero return command
FWD JOG command
RVS JOG command
The table below shows the input No. when the dedicated inputs are used as general purpose
inputs. (Those for the X axis only are available in the FX
Table 4.54: General purpose inputs
Details of command
ZRN
FWD
RVS
FX
-10GM
2N
Never
In Auto mode
Always
In Auto mode
Always
X axis
M9004
M9005
M9006
X axis
X375
X376
X377
-10GM) are used for general purpose inputs in
2N
FWD/RVS/ZRN signal valid
Always
Manu mode only
(not Auto mode).
Never
Manu mode only
(not Auto mode).
Never
-10GM.)
2N
Y axis
M9020
M9021
M9022
-10GM.))
2N
Y axis
X372
X373
X374
Parameters 4
FX
-20GM
2N
Special M signal valid
Always
Manu mode only
(not Auto mode).
Never
Always
Always
4-31