FX Series Positioning Controllers
Interrupt Drive Instructions
The inputs shown in the table below are assigned as the stop commands and deceleration
commands for interrupt drive control.
Table 5.15: Interrupt Drive Instructions
Input
X00
X01
X02
X03
X04
X05
X06
Because these inputs are treated as general-purpose inputs and can also be used with a man-
ual pulse generator they may not be available. (Refer to PARA. 39 (manual pulse generator)
described in Section 4.4.3.)
FX
-10GM
2N
cod 72 : x axis speed-change input
cod 72 : x axis stop input
cod 71 : x axis
cod 31
FX
-20GM
2N
cod 72 : x axis speed-change input
cod 72 : x axis stop input
cod 72 : y axis speed-change input
cod 72 : y axis stop input
cod 71 : x axis
cod 71 : y axis
cod 31 : Simultaneous 2-axis
Program format 5
5-34