FX Series Positioning Controllers
PARA. 2: Feed rate (The feed rate is expressed as "B".)
Set the travel of the machine per rotation of the motor.
Table 4.5: Feed rate
PARA. 3: Minimum command unit
Set the unit of travel specified by the positioning program.
Table 4.6: Minimum command unit
Setting in FX
2N
and FX
-10GM
2N
Set value: "0"
Set value: "1"
Set value: "2"
Set value: "3"
-1
*1: 10
inch = 2.54 mm
Example:
When PARA. 0 is set to "0", PARA. 3 is set to "2", and "x10
In the case of "cod 00 (DRV) x1000 y2000", x is set to "10 mm" and y is set to "20 mm".
When PARA. 0 is set to "1", PARA. 3 is set to "2", and "x10
In the case of "cod 00 (DRV) x1000 y2000", x is set to "10,000 PLS" and y is set to "20,000
PLS".
FX
-10GM
2N
1 to 999,999 × 10
-20GM
Set value "0" : Mechanical system of units.
Set value "2" : Combined system of units.
mm
0
10
-1
10
-2
10
-3
10
1 to 999,999 µm/REV
1 to 999,999 mdeg/REV
-1
minch/REV
PARA No.0
deg
0
10
-1
10
-2
10
-3
10
FX
-20GM
2N
Set value "1" Motor
system of units.
inch
*1
-1
10
-2
10
-3
10
-4
10
-2
mm" is selected:
1
PLS" is selected:
Parameters 4
PLS
3
10
2
10
1
10
0
10
4-9