Mitsubishi FX2N-10GM Hardware / Programming Manual page 103

Melsec-f
Hide thumbs Also See for FX2N-10GM:
Table of Contents

Advertisement

FX Series Positioning Controllers
Program in the programmable controller
PARA. 39: Manual pulse generator
Set whether or not to use manual pulse generators.
Table 4.42: Manual pulse generator
Setting = "0" : Invalid
Setting = "1" : Valid (one pulse generator).
Set the manual pulse generator using parameters on the X axis side. (The setting on the Y axis
side is ignored.)
In the FX
-20GM, both the X and Y axes can be operated by a manual pulse generator when
2N
only the X axis side is set.
When you enable manual pulse generators by setting PARA. 39 to "1" or "2", you should set
PARA. 40 to PARA. 42 also.
(In PARA. 40 to PARA. 42, set each of the X and Y axes respectively.)
PARA. 40: Multiplying factor per pulse generated by manual pulse generator
The input pulses are multiplied by a value set here, then output.
Table 4.43: Multiplying factor per pulse generated by manual pulse generator
X17
BIN [P] K2X20
m code
ON signal
(X27 to X20)BCD
DECO
Decode D0(7bit)
M 00
M 01
M 02
M 03
Auxiliary
equipment
operation
completion signal
M01
X 31
M03
X 33
Sequence for confirming
completion of the auxiliary
equipment operation
FX
-10GM
2N
FX
-10GM
2N
D 0
D 0(BIN)
D 0
M 00
K 7
(M99 to M00)
WAIT indication
Y10
X 31
Auxiliary equipment
Y11
No.1
END indication
Y12
X 33
Auxiliary equipment
Y13
No.2
m code
m code
ON
OFF
signal
signal
X 17
Y00
Setting = "0" : Invalid
Setting = "1" : Valid (one pulse generator).
Setting = "2" : Valid (two pulse generators).
1 to 255
Parameters 4
FX
-20GM
2N
FX
-20GM
2N
4-27