5.10.11 FNC14 (RMOV): Reduction transfer
FNC 14
RMOV
REDUCE
MOVE
devices
Applicable
devices
and basic
format
X24
FNC 14
When X24 is turned ON, the most significant bit in (S x ) is transmitted to most significant bit in
(D x ). Other bits are transmitted in turn from the least significant bit. b15 to b30 are ignored
and not transmitted.
Reduction transfer
RMOV
16-bit operation
5 steps
Word
K,H
KnX
KnY
Drive
input
FNC 14
RMOV
Transfer
source
32-bit
D 6
D 4
RMOV
(not V.)
KnM
D
V,Z
(not Z.)
The data in the 32-bit device
the 16-bit device
Transfer
destination
16-bit
·
When X24 is turned ON, the contents of D6 and
D7 are transmitted to D4.
Program format 5
Applicable models
Series name
FX
-10GM
2N
FX
-20GM
2N
is transmitted to
retaining the sign bit.
5-54
Remarks