FX Series Positioning Controllers
Setting the operation mode.
Set the commands for start/stop, return to the mechanical zero point (ZRN), manual forward
movement (FWD) and manual backward movement (RVS).
These commands can also be given from the input terminal of the FX
Both the commands from the program and the commands from the input terminal are pro-
cessed in parallel and become valid inside the FX
X000
X001
M8000
M101 Start
M102 Stop
M100 Single-step mode.
M103 m code OFF command.
M104
M105
M106
M107 Error reset
FNC 79
K 0
K 20 K2M100
TO
-10GM.
2N
Return to the mechanical
zero point (ZRN).
Manual backward
movement (FWD).
Manual backward
movement (RVS).
Programmable
K 1
controller
M107 to M100
Program Examples 9
-10GM.
2N
To be programmed upon
necessity.
Not used in this example.
#20
b7 to b0