Positioning In Which Movement Quantity Is Variable (Fx 2N -10Gm, Fx 2N -20Gm) - Mitsubishi FX2N-10GM Hardware / Programming Manual

Melsec-f
Hide thumbs Also See for FX2N-10GM:
Table of Contents

Advertisement

FX Series Positioning Controllers
9.5.2
Positioning in which movement quantity is variable (FX
1) Outline of positioning
A digital switch is connected to the FX
tioning address input via the digital switch to the positioning unit, then the positioning unit
performs positioning.
2) Operating procedure
c An arbitrary address (absolute value) for positioning is set via a digital switch.
d When the START signal (X010) is input, the machine returns to the zero point only at the
first time, then moves to the specified position.
3) Operation chart
4) Program
Line No.
Ox0, N0
N1
N2
N3
N4
N5
5) Parameter
Set the positioning parameter No. 16 (mechanical zero point address) to "0". For other
parameters, refer to Paragraph 9.2.4.
Speed
Zero point
Instruction
LD M9057;
FNC00(CJ) P0;
cod28(DRVZ);
P0;
cod00(DRV) xDD100; Moves the machine to the position specified by D101
m02(END);
-10GM, FX
2N
Series PLC, the PLC transfers an arbitrary posi-
2N
Distance
Set value
Return to the zero point
Description
Jumps to P0 if the zero point return completion flag
M9057 is ON.
Returns the machine to the zero point.
and D100.
D101 and D100 correspond to the buffer memories
#101 and #100, and the data is transferred from the
PLC by the T0 instruction.
Program Examples 9
-20GM)
2N
9-25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx2n-20gm

Table of Contents