Mitsubishi Q00JCPU User Manual page 798

Hide thumbs Also See for Q00JCPU:
Table of Contents

Advertisement

APPENDICES
Number
Name
SM415
2n (ms) clock
SM420
User timing clock No.0
SM421
User timing clock No.1
SM422
User timing clock No.2
SM423
User timing clock No.3
SM424
User timing clock No.4
SM430
User timing clock No.5
SM431
User timing clock No.6
SM432
User timing clock No.7
SM433
User timing clock No.8
SM434
User timing clock No.9
Number
Name
Low speed program
SM510
execution flag
Reads module service
SM551
interval
Number
Name
Program to program I/
SM580
O refresh
*1: This applies to the CPU of function version B or later.
App
- 9
Appendix 1 Special Relay List
Meaning
• This relay alternates between ON and OFF at
intervals of the time (unit: ms) specified in SD415.
• When Programmable Controller power supply is
turned OFF or a CPU module reset is performed,
n(ms)
n(ms)
goes from OFF to start.
(Note that the ON-OFF status changes when the
designated time has elapsed during the execution of
the program.)
• Relay repeats ON/OFF switching at fixed scan
intervals.
• When Programmable Controller power supply is
turned ON or a CPU module reset is performed,
goes from OFF to start.
(For the redundant CPU, however, this relay is
always OFF after system switching.)
• The ON/OFF intervals are set with the DUTY
instruction
n2 scan
n2 scan
n1 scan
• For use with SM420 to SM424 low speed programs
(4) Scan information
Meaning
OFF : Completed or not
• Goes ON when low speed execution type program is
executed
executed.
ON : Execution under way.
• When this relay goes from OFF to ON, the module
OFF : Ignored
service interval designated by SD550 is read to
ON : Read
SD551 to SD552.
(5) I/O refresh
Meaning
• When this special relay is turned ON, I/O refresh is
performed after execution of the first program, and
the next program is then executed.
OFF : Not refreshed
When a sequence program and an SFC program are
ON : Refreshed
to be executed, the sequence program is executed,
I/O refresh is performed, and the SFC program is
then executed.
TableApp.4 Special relay
Explanation
DUTY
n1
n2
n1: ON scan interval
n2: OFF scan interval
TableApp.5 Special relay
Explanation
TableApp.6 Special relay
Explanation
ponding
Set by
(When Set)
M9
S (Status change)
S (Every END
processing)
SM420
S (Every END
processing)
ponding
Set by
(When Set)
M9
S (Every END
processing)
U
ponding
Set by
(When Set)
M9
U
Corres-
Corresponding
ACPU
CPU
Qn(H)
QnPH
New
QnPRH
QnU
M9020
M9021
M9022
M9023
M9024
QnA
New
Qn(H)
QnPH
Corres-
Corresponding
ACPU
CPU
QnA
New
Qn(H)
QnPH
QnA
Qn(H)
New
QnPH
QnPRH
Rem
Corres-
Corresponding
ACPU
CPU
*1
New
Q00J/Q00/Q01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents