Mitsubishi Q00JCPU User Manual page 794

Hide thumbs Also See for Q00JCPU:
Table of Contents

Advertisement

APPENDICES
Number
Name
Device range check
SM237
inhibit flag
SM240
No. 1 CPU reset flag
SM241
No. 2 CPU reset flag
SM242
No. 3 CPU reset flag
SM243
No. 4 CPU reset flag
SM244
No. 1 CPU error flag
SM245
No. 2 CPU error flag
SM246
No. 3 CPU error flag
SM247
No. 4 CPU error flag
SM250
Max. loaded I/O read
SM251
I/O change flag
SM252
I/O change OK
*1: This applies to the CPU of function version B or later.
*5: The Universal model QCPU except the Q02UCPU.
*6: This applies to the Q02UCPU, Q03UDCPU, Q04UDHCPU, Q06UDHCPU whose first 5 digits of serial number is "10012" or later, and the Q13UDHCPU,
Q26UDHCPU.
App
- 5
Appendix 1 Special Relay List
TableApp.3 Special relay
Meaning
OFF : Check device range
• Selects whether or not to check the device range by
ON : Do not check device
the BMOV/FMOV instruction (Only when the sub-set
range
condition is established).
• Goes OFF when reset of the No. 1 CPU is canceled.
OFF : No. 1 CPU reset
• Comes ON when the No. 1 CPU is resetting
cancel
(including the case where the CPU module is
ON : No. 1 CPU resetting
removed from the base).
The other CPUs are also put in reset status.
• Goes OFF when reset of the No. 2 CPU is canceled.
• Comes ON when the No. 2 CPU is resetting
OFF : No. 2 CPU reset
(including the case where the CPU module is
cancel
removed from the base).
ON : No. 2 CPU resetting
The other CPUs result in "MULTI CPU DOWN" (error
code: 7000).
• Goes OFF when reset of the No. 3 CPU is canceled.
OFF : No. 3 CPU reset
• Comes ON when the No. 3 CPU is resetting
cancel
(including the case where the CPU module is
ON : No. 3 CPU resetting
removed from the base).The other CPUs result in
"MULTI CPU DOWN" (error code: 7000).
• Goes OFF when reset of the No. 4 CPU is canceled.
OFF : No. 4 CPU reset
• Comes ON when the No. 4 CPU is resetting
cancel
(including the case where the CPU module is
ON : No. 4 CPU resetting
removed from the base).The other CPUs result in
"MULTI CPU DOWN" (error code: 7000).
• Goes OFF when the No. 1 CPU is normal (including
OFF : No. 1 CPU normal
a continuation error).
ON : No. 1 CPU during stop
• Comes ON when the No. 1 CPU is during a stop
error
error.
• Goes OFF when the No. 2 CPU is normal (including
OFF : No. 2 CPU normal
a continuation error).
ON : No. 2 CPU during stop
• Comes ON when the No. 2 CPU is during a stop
error
error.
• Goes OFF when the No. 3 CPU is normal (including
OFF : No. 3 CPU normal
a continuation error).
ON : No. 3 CPU during stop
• Comes ON when the No. 3 CPU is during a stop
error
error.
• Goes OFF when the No. 4 CPU is normal (including
OFF : No. 4 CPU normal
a continuation error).
ON : No. 4 CPU during stop
• Comes ON when the No. 4 CPU is during a stop
error
error
OFF : Ignored
• When this relay goes from OFF to ON, maximum
ON : Read
loaded I/O number is read to SD250.
• By turning this relay ON after setting the head I/O
number of the replaced I/O module to SD251, the I/O
module can be replaced online (with power on).
(Only one module can be replaced for each setting.)
OFF : No replacement
• Turn this relay ON in the test mode of the program or
ON : Replacement
peripheral device for an I/O module change during
RUN, or in the test mode of the peripheral device for
an I/O change during STOP.
• Do not execute a RUN/STOP mode change until I/O
module change is finished.
OFF : Replacement
prohibited
• Goes ON when I/O replacement is OK.
ON : Replacement enabled
Explanation
Corres-
ponding
Set by
Corresponding
ACPU
(When Set)
M9
U
New
S (Status change)
New
S (Status change)
New
U
New
U
M9094
S (END)
New
CPU
*6
QnU
*1
Q00/Q01
*1
Qn(H)
QnPH
QnU
*1
Qn(H)
QnPH
*5
QnU
*1
Q00/Q01
*1
Qn(H)
QnPH
QnU
*1
Qn(H)
QnPH
*5
QnU
QnA
Qn(H)
QnPH
QnPRH
Rem
Q2A(S1)
Q3A
Q4A
Q4AR

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents