Mitsubishi Q00JCPU User Manual page 714

Hide thumbs Also See for Q00JCPU:
Table of Contents

Advertisement

10
DEVICE EXPLANATION
(3) Interrupt factors
Interrupt factor
*1, *10
Interrupt module
Special function module
for starting sequence
Internal timer
I28 to 31, I49
*5
Error
Multiple CPU
synchronization
Intelligent function
module
10
- 99
10.11 Interrupt pointer (I)
Table10.21 indicates the interrupt factors of the interrupt pointers.
Table10.21 Interrupt factor classification
Interrupt
Description
pointer No.
Interrupt input from the interrupt
I0 to 15
*1
module
Interrupt from the AnS/A series
compalible special function
I16 to 27
module that can make the CPU
module start an interrupt.
Fixed scan interrupt by the
internal timer of the CPU module.
Interrupt made by occurrence of
I32 to 41
error that continues sequence
program operation.
The fixed scan interrupt to
execute control with
I45
synchronizing the operation cycle
of the Motion controller with
interrupt cycle.
Interrupt from the intelligent
*7
I50 to 255
function module.
* 1 : Refer to the following manual for the available interrupt modules.
QCPU User's Manual (Hardware Design, Maintenance and Inspection)
* 2 : The interrupt pointer I49 (high-speed interrupt function dedicated pointer) is available for the QnHCPU only.
* 3 : The Q02CPU cannot use the interrupt pointer I49 (high-speed interrupt function dedicated pointer).
* 4 : The interrupt pointers I40, I41 are available for the Redundant CPU only.
* 5 : For the error to which the error-time operation mode can be set in the PLC RAS setting of the PLC parameter
dialog box, an interrupt is executed only when the setting is "Continue".
* 6 : Applicable for the Universal model QCPU and Motion controller that are compatible with the multiple CPU high
speed main base unit (Q3
Not applicable for the single CPU system using the Universal model QCPU.
* 7 : The Basic model QCPU is I50 to 127.
* 8 : The target module is serial communication module, MELSECNET/H module, Ethernet module, and high-speed
counter module.
For details, refer to the manual for each module.
* 9 : The target module is the intelligent communication module etc.
For details, refer to the manual for each module.
* 10 : When using the interrupt module with the High Performance model QCPU, check the versions of the CPU
module and GX Developer. (
POINT
To use the intelligent function module interrupt (
function module setting (interrupt points setting) is required at the "PLC system"
tab screen in the "(PLC) Parameter" dialog box.
Basic
model
Performance
QCPU
model QCPU
*2
*8
: Available
: Some interrupt pointers unavailable
DB) and multiple CPU high speed transmission.
Appendix 4.2)
Applicable CPU module
High
Process
Redundant
CPU
CPU
*3
*2
*2
*4
*4
Section 6.23), the intelligent
Universal
model
QCPU
*2
*6
: N/A