A.3.2   Mistaken Setting Of A Bb-Id Other Than Bb#00 Or Bb#01 - Fujitsu M10 Installation Manual

Hide thumbs Also See for M10:
Table of Contents

Advertisement

Continue?[yes/no](default   no):yes  
The   initialization   of   XSCF   will   be   started.  
    XSCF         :   all   data   clear   (exclude   SYSTEM   ID   data)  
    BACK   UP   :   all   data   clear   (exclude   SYSTEM   ID   data)  
XSCF   will   be   automatically   rebooted.   Afterwards,   XSCF   will   be   initialized.  
Continue?[yes/no](default   no):yes  
Disabling   IDIAG   prompt   complete  
Setting   FRUID-ROM   to   writable   complete  
Clear   BB-ID   complete  
Backup   common   DB   complete  
Syncing   file   systems...     complete  
XSCF   shutdown   request   was   completed.  
4.
Confirm that all LEDs on the operation panel are off.
5.
Remove the power cords from the power supply units.
6.
Change the BB-IDs to the correct settings.
For details, see
7.
Perform steps 1 to 6 for all chassis.
8.
Connect the power cords of all chassis to the power supply units.
9.
Connect the system management terminal to the serial port of the master
XSCF.
10. Proceed with work by returning to
A.3.2
Mistaken setting of a BB-ID other than BB#00 or
BB#01
If the setting of a BB-ID other than BB#00 or BB#01 is incorrect when the input power
is turned on, restore it according to the following procedure.
Fujitsu M10/SPARC M10 Systems Installation Guide ・ July 2015
318
"4.1 Setting the ID (BB-ID) Identifying a
"6.3 Logging In to the
Chassis."
XSCF."