Fujitsu M10 Installation Manual page 302

Hide thumbs Also See for M10:
Table of Contents

Advertisement

M10-4S.
12. Remove the XSCF BB control cables from the target SPARC M10-4S.
13. Remove the crossbar cables from the target SPARC M10-4S.
14. You are performing removal to the 1BB configuration. So, remove the XSCF
DUAL control cable.
15. Remove the target SPARC M10-4S from the rack.
Remove the SPARC M10-4S from the rack by reversing the mounting procedure.
For the procedure for mounting in the rack, see
M10-4/SPARC M10-4S in a
10.2.2
Removing the server after stopping the target
physical partition (PPAR)
This section describes the SPARC M10-4S removal procedure for reducing to a 1BB
configuration after stopping the target physical partition (PPAR).
Stop applications in guest domains as required.
For details on the XSCF commands executed in each step, see the Fujitsu M10/SPARC
M10 Systems XSCF Reference Manual.
1.
Log in to the master XSCF.
Execute the showbbstatus command to confirm that the XSCF to which you have
logged in is the master XSCF.
If it is a standby XSCF, retry to log in to the master XSCF.
XSCF>   showbbstatus
BB#00   (Master)
2.
Execute the showhardconf command, and confirm the chassis serial number
of the system board (PSB) targeted for release.
For details, see
Note - If the serial number of the target chassis is being used as the system serial number, the
initbb command cannot release the chassis. In this case, execute the switchscf command to
switch the master XSCF.
3.
Execute the poweroff command to stop all the physical partitions including
the SPARC M10-4S to be removed.
Specify the target PPAR number in ppar_id.
XSCF>   poweroff -p  ppar_id
The following example stops PPAR#0.
Fujitsu M10/SPARC M10 Systems Installation Guide ・ July 2015
288
rack."
"A.2.1 Checking the component
"3.4.2 Mounting the SPARC
status."