#   ldm list-io
NAME                                                                             TYPE       BUS             DOMAIN       STATUS
----                                                                             ----       ---             ------       ------
PCIE0                                                                           BUS         PCIE0         primary     IOV
PCIE1                                                                           BUS         PCIE1         root-dom0IOV
PCIE2                                                                           BUS         PCIE2         root-dom0IOV
PCIE3                                                                           BUS         PCIE3         root-dom0IOV
PCIE4                                                                           BUS         PCIE4         primary     IOV
PCIE5                                                                           BUS         PCIE5         root-dom0IOV
PCIE6                                                                           BUS         PCIE6         root-dom0IOV
PCIE7                                                                           BUS         PCIE7         root-dom0IOV
PCIE8                                                                           BUS         PCIE8                          
PCIE9                                                                           BUS         PCIE9         root-dom1IOV
PCIE10                                                                         BUS         PCIE10       root-dom1IOV
PCIE11                                                                         BUS         PCIE11       root-dom1IOV
PCIE12                                                                         BUS         PCIE12                        
PCIE13                                                                         BUS         PCIE13       root-dom1IOV
PCIE14                                                                         BUS         PCIE14       root-dom1IOV
PCIE15                                                                         BUS         PCIE15       root-dom1IOV
....
/BB1/CMUL/NET0                                                         PCIE       PCIE8                           UNK
/BB1/CMUL/SASHBA                                                     PCIE       PCIE8                           UNK
/BB1/PCI0                                                                   PCIE       PCIE9         root-dom1OCC
/BB1/PCI3                                                                   PCIE       PCIE10       root-dom1OCC
/BB1/PCI4                                                                   PCIE       PCIE10       root-dom1OCC
/BB1/PCI7                                                                   PCIE       PCIE11       root-dom1OCC
/BB1/PCI8                                                                   PCIE       PCIE11       root-dom1OCC
/BB1/CMUL/NET2                                                         PCIE       PCIE12                         UNK
/BB1/PCI1                                                                   PCIE       PCIE13       root-dom1OCC
/BB1/PCI2                                                                   PCIE       PCIE13       root-dom1OCC
/BB1/PCI5                                                                   PCIE       PCIE14       root-dom1OCC
/BB1/PCI6                                                                   PCIE       PCIE14       root-dom1OCC
/BB1/PCI9                                                                   PCIE       PCIE15       root-dom1OCC
/BB1/PCI10                                                                 PCIE       PCIE15       root-dom1OCC
b. Stop and release the root domain where the root complexes of SPARC
#   ldm stop-domain root-dom1
LDom   root-dom1   stopped
#   ldm unbind-domain root-dom1
#   ldm list-domain
NAME                           STATE             FLAGS       CONS         VCPU     MEMORY       UTIL     UPTIME
primary                     active           -n-cv-     UART         16         14G             0.2%     4h   59m
guest0                       active           -n----     5100         32         32G             0.0%     1h   55m
guest1                       active           -n----     5101         32         32G             0.0%     1h   46m
"/BB1/". Then, PCIE9, PCIE10, PCIE11, PCIE13, PCIE14, and PCIE15, which
are the root complexes (BUS) of the PCIe end point, are assigned to root-dom1.
M10-4S to be released are assigned.
In the next example, we can confirm that the ldm stop-domain command and
the ldm unbind-domain command are executed, the root domain (root-
dom1) is released, and the root domain becomes inactive state.