Installing The Server After Turning Off The Input Power To The Entire System - Fujitsu M10 Installation Manual

Hide thumbs Also See for M10:
Table of Contents

Advertisement

XSCF>   poweron -y -p 0
14. Execute the showpparstatus command to check the operation status of the
physical partition.
In the following example, the [PPAR Status] field displays "Running," so the
physical partition is operating correctly.
XSCF>   showpparstatus -p 0
PPAR-ID   PPAR   Status
00             Running
15. Execute the showboards command to check the system board (PSB) status.
In the following example, since both the [Conn] and [Conf] fields display "y" for
system board 02-0, the system board (PSB) has been added correctly.
XSCF>   showboards -p 0
PSB     PPAR-ID(LSB)   Assignment     Pwr     Conn   Conf   Test         Fault
----   ------------   -----------   ----   ----   ----   -------   --------
00-0   00(00)               Assigned         y         y         y         Passed     Normal
01-0   00(01)               Assigned         y         y         y         Passed     Normal  
02-0   00(02)               Assigned         y         y         y         Passed     Normal  
16. Reconfigure the logical domains.
Assign the resources of the installed SPARC M10-4S to an existing logical
domain or a newly configured logical domain. For details, see the Fujitsu
M10/SPARC M10 Systems Domain Configuration Guide.
After the reconfiguration, execute the ldm add-spconfig command to save the
logical domain configuration in the XSCF.
9.2.3
Installing the server after turning off the input power
to the entire system
This section describes the procedure for installing the SPARC M10-4S after stopping
the entire system while work is in progress and turning off the input power.
 
For details on the XSCF commands executed in each step, see the Fujitsu M10/SPARC
M10 Systems XSCF Reference Manual.
Note - Suppose you install the SPARC M10-4S together with a PCI expansion unit connected
to it and set the enabling/disabling setting of the direct I/O function of the PCI expansion
unit. Then, at the next startup, the logical domain configuration of the physical partition
resets to the factory-default state. See "1.7.2 Notes on using the direct I/O function" and "1.7.3
How to save/restore the logical domain configuration information and the OpenBoot PROM
environment variable" in the PCI Expansion Unit for Fujitsu M10/SPARC M10 Systems Service
Manual and take action.
Fujitsu M10/SPARC M10 Systems Installation Guide ・ July 2015
260