XSCF>   showboards -a
PSB     PPAR-ID(LSB)   Assignment     Pwr     Conn   Conf   Test         Fault
----   ------------   -----------   ----   ----   ----   -------   --------
00-0   SP                       Available       n         n         n         Passed     Normal
01-0   SP                       Available       n         n         n         Passed     Normal
02-0   SP                       Available       n         n         n         Passed     Normal
03-0   SP                       Available       n         n         n         Passed     Normal
7.
Execute the initbb command from the master XSCF to release the target
SPARC M10-4S from the system and initialize it.
In bb_id, specify the ID (BB-ID) identifying the chassis.
XSCF>   initbb -b bb_id
The following example releases BB#03 from the system and initializes it.
XSCF>   initbb -b 3
You   are   about   to   initialize   BB/XB-Box.
NOTE   the   following.
1.   BB/XB-Box   is   excluded   from   the   system   and   halted.
2.   PPAR-ID   of   the   same   value   as   BB-ID   becomes   invalid.
Continue?   [y|n]   : y
Note - After the execution of the initbb command, the target chassis is released from the
system and enters the stopped state. Do not disconnect the power cords or various cables
until the XSCF STANDBY LED on the panel and the rear READY LED of the target chassis
are off.
Note - For the initialization of the chassis of the master XSCF, perform that work at the end.
Execute the restoredefaults -c factory command to return to the factory defaults, including
the CPU Activation key information. Perform this work with a serial connection to the
master XSCF.
For XCP 2041 or later, execute the restoredefaults -c factory -r activation command.
The key must be reinstalled at initial setup of the XSCF after installation.
8.
Remove the power cords from the power supply units of the target SPARC
M10-4S.
9.
Remove the XSCF BB control cables from the target SPARC M10-4S.
10. Remove the crossbar cables from the target SPARC M10-4S.
11. You are performing removal to the 1BB configuration. So, remove the XSCF
DUAL control cable.
12. Remove the target SPARC M10-4S from the rack.
Remove the SPARC M10-4S from the rack by reversing the mounting procedure.
For the procedure for mounting in the rack, see
M10-4/SPARC M10-4S in a
Fujitsu M10/SPARC M10 Systems Installation Guide ・ July 2015
292
"3.4.2 Mounting the SPARC
rack."