Msg: Cable connection test failure
Date: Nov 08 11:01:38 JST 2012
Code: 10000008-007cff0000ff0000ff-019204310000000000000000
Status: Information Occurred: Nov 08 11:01:32.839 JST 2012
FRU : /BB#1/XBU#0/CBL#0L
Msg: Cable connection test failure
Date: Nov 08 11:01:43 JST 2012
Code: 10000008-007cff0000ff0000ff-019204310000000000000000
Status: Information Occurred: Nov 08 11:01:33.411 JST 2012
FRU : /BB#0/XBU#0/CBL#0R
Msg: Cable connection test failure
Date: Nov 08 11:01:44 JST 2012
Code: 10000008-007cff0000ff0000ff-019204310000000000000000
Status: Information Occurred: Nov 08 11:01:33.617 JST 2012
FRU : /BB#0/XBU#0/CBL#0L
Msg: Cable connection test failure
Figure A-1 Incorrect 0L and 0R cable connections (reversed cable connections)
BB#0 XBU#0
2R
2L
1R
1L
0R
0L
A.2.3
Checking information on a component where a
failure or degradation occurred
Use the showstatus command to check information on a degraded unit among the
FRUs composing the system.
showstatus command
The command displays information on the unit where a failure has occurred and on
units on upper layers, among the field replaceable units composing the system. The
mark indicating the status (*) appears at the beginning of the line of the displayed
unit. Status displays the unit status.
BB#01 XBU#0
2R
2R
2L
2L
1R
1R
1L
1L
0R
0R
0L
0L
2R
2L
1R
1L
0R
0L
Appendix A Troubleshooting
311