Figure 10-1     Configuration example of 2BB
BB#0
guest0
core
MEM
root-dom0
MEM
core
primary
core
MEM
PPAR#0
1.
Log in to the master XSCF.
Execute the showbbstatus command to confirm that the XSCF to which you have
logged in is the master XSCF.
If it is a standby XSCF, retry to log in to the master XSCF.
XSCF>   showbbstatus
BB#00   (Master)
2.
Execute the showhardconf command, and confirm the chassis serial number
of the system board (PSB) targeted for release.
For details, see
"A.2.1 Checking the component
Note - If the serial number of the target chassis is being used as the system serial number, the
initbb command cannot release the chassis. In this case, execute the switchscf command to
Chapter 10 Removing a System with a Building Block Configuration
BB#1
guest1
vdisk,
vdisk,
core
vnet
vnet
root-dom1
RC
I/Os
RC
I/Os
SYSVOL
vdisk,
MEM
vnet
core
MEM
I/Os
Mirroring
status."
vdisk,
vnet
RC
I/Os
RC
SYSVOL
279