Fujitsu M10 Installation Manual page 189

Hide thumbs Also See for M10:
Table of Contents

Advertisement

4.
Place the crossbar cables connected to the 2L and 2R ports of each XBU
together at the right side as viewed from the rear of the rack.
5.
If a cable holder is supplied with the rack used, secure the crossbar cables
placed together at the right side to the cable holder of the rack.
Figure 5-16     Example of stored cables (4BB configuration)
BB#03
BB#02
BB#01
BB#00
3BB configuration
For the 3BB configuration, place the crossbar cables connected to the 1L and 1R ports
of XBU#0/#1 together at the right side as viewed from the rear of the rack. Place the
other crossbar cables together at the left side as viewed from the rear of the rack.
1.
Hang the power cords from the left side as viewed from the rear of the rack.
Place the power cords over the cable support fixing bracket to hang them there
as is.
2.
Place the crossbar cables connected to the 0L/0R and 2L/2R ports of each
XBU together at the left side as viewed from the rear of the rack.
3.
Secure the crossbar cables placed together at the left side to the cable
2L/2R
1L/1R
0L/0R
2L/2R
1L/1R
0L/0R
2L/2R
1L/1R
0L/0R
2L/2R
1L/1R
0L/0R
Chapter 5 Connecting Cables to the Chassis