Removal Of Expansion Rack 2, And Decrease In The Number Of Sparc M10-4S Units To Four Or Less - Fujitsu M10 Installation Manual

Hide thumbs Also See for M10:
Table of Contents

Advertisement

10.3
Removal of Expansion Rack 2, and
Decrease in the Number of SPARC
M10-4S Units to Four or Less
This section describes the procedure to remove the expansion rack 2 and set four or
less SPARC M10-4S on the expansion rack 1 (connection via crossbar box). This
procedure corresponds to pattern C in
during this work.
 
For details on the XSCF commands executed in each step, see the Fujitsu M10/SPARC
M10 Systems XSCF Reference Manual.
1.
Log in to the master XSCF.
Execute the showbbstatus command to confirm that the XSCF to which you have
logged in is the master XSCF.
If it is a standby XSCF, retry to log in to the master XSCF.
XSCF>   showbbstatus
BB#00   (Master)
2.
Execute the showhardconf command, and confirm the chassis serial number
of the system board (PSB) targeted for release.
For details, see
Note - If the serial number of the target chassis is being used as the system serial number, the
initbb command cannot release the chassis. In this case, execute the switchscf command to
switch the master XSCF.
3.
Execute the poweroff command to stop all the physical partitions.
XSCF>   poweroff -y  -a
PPAR-IDs   to   power   off:00,01,02,03,04,05,06,07,08,09,10,11
Continue?   [y|n]: y
00:Powering   off
01:Powering   off
02:Powering   off
03:Powering   off
04:Powering   off
05:Powering   off
06:Powering   off
07:Powering   off
08:Powering   off
09:Powering   off
10:Powering   off
11:Powering   off
Figure
"A.2.1 Checking the component
Chapter 10 Removing a System with a Building Block Configuration
8-3. You need to stop the system
status."
293