entire system is turned off.
9.2.1
Installing the server while the target physical
partition (PPAR) is operating
This section describes the SPARC M10-4S installation procedure for expanding a 1BB
configuration to a 2BB configuration while the target physical partition (PPAR) and
the control domain are operating. To perform maintenance while the physical
partition (PPAR) is operating, use dynamic reconfiguration (DR) for the physical
partition.
For the software requirements required for this operation, see the latest Product Notes.
For details on the XSCF commands executed in each step, see the Fujitsu M10/SPARC
M10 Systems XSCF Reference Manual.
For details on the installation procedure for expanding a 1BB configuration to a 2BB
configuration, see also "A.4 For Expansion of a Newly Installed System of Version
XCP 2220 or Later from 1BB to 2BB Configuration" in the Fujitsu M10/SPARC M10
Systems Domain Configuration Guide.
1.
Log in to the master XSCF.
Execute the showbbstatus command to confirm that the XSCF to which you have
logged in is the master XSCF.
If it is a standby XSCF, retry to log in to the master XSCF.
XSCF>   showbbstatus
BB#00   (Master)
2.
Execute the showsscp command to check whether the IP address of the SP to
SP communication protocol (SSCP) is a default value or a value set by a user.
XSCF>   showsscp
Note - For details on the default SCCP IP address, see "3.7.5 Understanding the IP addresses
that are set with SSCP" in the Fujitsu M10/SPARC M10 Systems System Operation and
Administration Guide.
If the IP address is a default value and the default value should also be used for
the IP address of the SPARC M10-4S to be installed, go to the next step.
To set a user value, use the setsscp command to set an IP address, use the
applynetwork command to apply the SSCP IP address of the target SPARC
M10-4S, and confirm that it was reflected. Then, execute the rebootxscf
command to complete settings, and go to the next step. For details on the
procedure, see
3.
Install the SPARC M10-4S.
a. Execute the addfru command, and install the SPARC M10-4S by following
"7.5.6 Applying network
the messages.
Chapter 9 Installing a System with a Building Block Configuration
settings."
241