connected to it and set the enabling/disabling setting of the direct I/O function of the PCI
expansion unit. In this case, execute the setpciboxdio command to set the enabling/disabling
setting before installing it on the physical partition by executing the addboard command.
When you have changed the setting of the direct I/O function, do not restart the logical
domains until you execute the ldm add-spconfig command to save the logical domain
configuration in XSCF.
Note - Pull out all the PCIe cassettes with the PCIe card for the PCI expansion unit to be
installed. After incorporating the link card into the server, attach the pulled-out PCIe cassette
to the PCI expansion unit. Then, install the PCIe card of the PCI expansion unit on the server
by using PHP.
a. Return to the XSCF shell, execute the showboards command, and check
XSCF>   showboards -p 0
PSB     PPAR-ID(LSB)   Assignment     Pwr     Conn   Conf   Test         Fault
----   ------------   -----------   ----   ----   ----   -------   --------
00-0   00(00)               Assigned         n         n         n         Passed     Normal  
01-0   00(01)               Assigned         n         n         n         Passed     Normal
02-0   SP                       Available       n         n         n         Passed     Normal
b. Execute the addboard command to assign the system board (PSB).
XSCF>   addboard -c assign -p 0 02-0
PSB#02-0   will   be   assigned   into   PPAR-ID   0.   Continue?[y|n]   : y
c. Execute the showresult command to confirm the end status of the
XSCF>   showresult
0
d. Execute the showboards command to check the system board (PSB)
XSCF>   showboards -p 0
PSB     PPAR-ID(LSB)   Assignment     Pwr     Conn   Conf   Test         Fault
----   ------------   -----------   ----   ----   ----   -------   --------
00-0   00(00)               Assigned         n         n         n         Passed     Normal  
01-0   00(01)               Assigned         n         n         n         Passed     Normal
02-0   00(02)               Assigned         n         n         n         Passed     Normal
13. Start the physical partition.
The following example starts PPAR#0.
the system board (PSB) status.
In the following example, system board 02-0 is in the system board pool.
The following example assigns system board 02-0 to physical partition 0.
previously executed addboard command.
In the following example, 0 is returned as the end status, so the execution of
the addboard command has completed correctly.
status, and confirm that the system board (PSB) has been added.
Chapter 9 Installing a System with a Building Block Configuration
259