Mounting The Sparc M10-1 In A Rack - Fujitsu M10 Installation Manual

Hide thumbs Also See for M10:
Table of Contents

Advertisement

3.4.1

Mounting the SPARC M10-1 in a rack

1.
Confirm that the rack rail kit supplied with the SPARC M10-1 is complete.
Figure 3-25     Rack rail kit
Number in figure Name
1
2
2.
Confirm that the rack is fixed in place to prevent the rack from toppling over.
For details, see
3.
Confirm the chassis mounting location in the rack.
a. Confirm the mounting location in the rack. If necessary, mark the location on
b. Confirm that the chassis mounting location is the same on the front and rear
c. Remove the inner rail from the slide rail.
d. Pull out the inner rail by releasing the lock on the inner rail.
e. Release the lock on the middle rail, and store it in the outer rail.
4.
Attach the slide rail to the rack.
a. Confirm the attachment direction of the slide rail.
b. From the front of the rack, attach the slide rail to the rear supporting column
Fujitsu M10/SPARC M10 Systems Installation Guide ・ July 2015
96
Slide rail (left/right)
Cable management arm
"3.3.2 Securing the
the supporting columns.
columns.
The inner rail is attached to the chassis in step 6.
The [R] mark on the slide rail indicates the right side, and the [L] mark
indicates the left side. The [FRONT] mark on the slide rail should be
positioned at the front of the rack.
of the rack. At this time, attach the slide rail brackets to the supporting
FRONT
Quantity
1 per side
1
rack."
REAR
(1)
(2)