A.2.4   Checking Diagnosis Results - Fujitsu M10 Installation Manual

Hide thumbs Also See for M10:
Table of Contents

Advertisement

Status: Description
Faulted: Non-operational status of the relevant component due to failure
Degraded: A part of the unit has failed, but the unit continues in operation.
Deconfigured: The unit including its components on the lower layers is in a
normal condition, but it has been degraded due to the influence of a failure or
degradation of another unit.
Maintenance: Maintenance work in progress. The replacefru command, addfru
command, or initbb command is in operation.
Example: Display example where a CPU and memory of the CPU memory unit
(lower) of BB#00 are degraded because of a failure
XSCF>   showstatus
    BB#00;
                CMUL   Status:Normal;
*                       CPU#0   Status:Faulted;
*                       MEM#00A   Status:Faulted;
 
 
Example: Display example where the memory on a motherboard unit is degraded
because of a failure
XSCF>   showstatus
        MBU   Status:Normal;
*               MEM#1B   Status:Deconfigur
A.2.4
Checking diagnosis results
Use the testsb command to perform an initial diagnosis of the specified physical
system board (PSB).
Use the diagxbu command to diagnose the crossbar cables and crossbar units
connected to the specified SPARC M10-4S chassis.
testsb command
The testsb command diagnoses the configuration of the specified PSB and the
operation of each device mounted on the PSB. After completing the diagnosis, the
command displays the results. You can also check the diagnosis results with the
display of "Test" and "Fault" by the showboards command.
 
The displayed diagnosis results from testsb are as follows:
PSB: PSB number
Test: Initial diagnosis status of the PSB
Unmount: The PSB cannot be recognized because it is not mounted or has failed.
Unknown: The PSB has not been diagnosed.
Fujitsu M10/SPARC M10 Systems Installation Guide ・ July 2015