Table 6-1     Terminal software setting value (continued)
Setting item
STOP bit
Flow control
Delay
2.
Confirm that the system management terminal is connected to the serial port
of the chassis.
For a building block configuration, confirm that the terminal is connected to the
serial port of the master XSCF.
Note - For direct connections between chassis, BB#00 is usually the master XSCF, and BB#01
is the standby XSCF. For connections through crossbar boxes, XBBOX#80 is usually the
master XSCF, and XBBOX#81 is the standby XSCF. If the master is switched, BB#01 or
XBBOX#81 becomes the master XSCF, and BB#00 or XBBOX#80 becomes the standby XSCF.
For the mounting locations of BB#00 and BB#01, see
conditions for general
6.2

Turning On the Input Power

This section describes the procedures for connecting the power cords to outlets,
turning on the input power, and starting the XSCF.
6.2.1
Checking the BB-ID settings (for the SPARC
M10-4S)
For the SPARC M10-4S, confirm that the BB-IDs are set properly before turning on
the input power.
Note - If a BB-ID is not set or incorrectly set when the input power is turned on, the XSCF
does not start normally. Therefore, confirm that the BB-ID settings are correct.
1.
Check the BB-IDs on the operation panel on the front of the SPARC M10-4S
chassis.
Confirm that BB-IDs 00 to 15 are set sequentially.
2.
Check the BB-IDs on the operation panel on the front of the crossbar box
chassis.
Confirm that BB-IDs 80 to 83 are set sequentially.
For details on setting them, see
Fujitsu M10/SPARC M10 Systems Installation Guide ・ July 2015
178
Value
1 bit
None
Other than 0
racks."
"4.1 Setting the ID (BB-ID) Identifying a
Figure 2-3
in
"2.4.1 Mounting
Chassis."