Quantities of mounted FRUs by FRU type, such as CPU, memory, and PCI card
■
Physical partition (PPAR) information
■
PCI expansion unit information (displayed only when the power to the physical
■
partition is on)
PCI card information (displayed only when the power to the physical partition is
■
on)
showhardconf command
Use the showhardconf command to check the system hardware configuration and
the status of each component.
A displayed asterisk (*) indicates the fault location regarding a unit where a failure or
degradation occurred.
Status displays the following statuses.
Faulted: Non-operational status of the relevant component due to failure
■
Degraded: A part of the unit has failed, but the unit continues in operation.
■
Deconfigured: The unit including its components on the lower layers is in a
■
normal condition, but it has been degraded due to the influence of a failure or
degradation of another unit.
Maintenance: Maintenance work in progress. The replacefru command, addfru
■
command, or initbb command is in operation.
Normal: Normal status
■
Example: SPARC M10-1 display example
XSCF> showhardconf -M
SPARC M10-1;
+ Serial:20xxxxxxxx; Operator_Panel_Switch:Service;
+ System_Power:Off; System_Phase:Cabinet Power Off;
Partition#0 PPAR_Status:Powered Off;
MBU Status:Normal; Ver:2209h; Serial:TZ01348006 ;
+ FRU-Part-Number:CA07363-D011 A0 /7088702 ;
+ Power_Supply_System: ;
+ Memory_Size:1024 GB; Type: B ;
CPU#0 Status:Normal; Ver:4141h; Serial:00010263;
+ Freq:3.200 GHz; Type:0x20;
+ Core:16; Strand:2;
MEM#00A Status:Normal;
+ Code:ce8001M386B8G70BO0-YH94 0000-2151EFEB;
+ Type:47; Size:64 GB;
MEM#01A Status:Normal;
+ Code:ce8001M386B8G70BO0-YH94 0000-2151EF8A;
+ Type:47; Size:64 GB;
MEM#02A Status:Normal;
+ Code:ce8001M386B8G70BO0-YH94 0000-23BE2621;
+ Type:47; Size:64 GB;
MEM#03A Status:Normal;
+ Code:ce8001M386B8G70BO0-YH94 0000-2151EFE0;
+ Type:47; Size:64 GB;
MEM#10A Status:Normal;
+ Code:ce8001M386B8G70BO0-YH94 0000-2151EF7E;
Appendix A Troubleshooting
299