Quantities of mounted FRUs by FRU type, such as CPU, memory, and PCI card
Physical partition (PPAR) information
PCI expansion unit information (displayed only when the power to the physical
partition is on)
PCI card information (displayed only when the power to the physical partition is
on)
showhardconf command
Use the showhardconf command to check the system hardware configuration and
the status of each component.
A displayed asterisk (*) indicates the fault location regarding a unit where a failure or
degradation occurred.
Status displays the following statuses.
Faulted: Non-operational status of the relevant component due to failure
Degraded: A part of the unit has failed, but the unit continues in operation.
Deconfigured: The unit including its components on the lower layers is in a
normal condition, but it has been degraded due to the influence of a failure or
degradation of another unit.
Maintenance: Maintenance work in progress. The replacefru command, addfru
command, or initbb command is in operation.
Normal: Normal status
Example: SPARC M10-1 display example
XSCF>   showhardconf -M
SPARC   M10-1;
        +   Serial:20xxxxxxxx;   Operator_Panel_Switch:Service;
        +   System_Power:Off;   System_Phase:Cabinet   Power   Off;
        Partition#0   PPAR_Status:Powered   Off;
        MBU   Status:Normal;   Ver:2209h;   Serial:TZ01348006     ;
                +   FRU-Part-Number:CA07363-D011   A0       /7088702                             ;
                +   Power_Supply_System:   ;
                +   Memory_Size:1024   GB;   Type:   B   ;
                CPU#0   Status:Normal;   Ver:4141h;   Serial:00010263;
                        +   Freq:3.200   GHz;   Type:0x20;
                        +   Core:16;   Strand:2;
                MEM#00A   Status:Normal;
                        +   Code:ce8001M386B8G70BO0-YH94   0000-2151EFEB;
                        +   Type:47;   Size:64   GB;
                MEM#01A   Status:Normal;
                        +   Code:ce8001M386B8G70BO0-YH94   0000-2151EF8A;
                        +   Type:47;   Size:64   GB;
                MEM#02A   Status:Normal;
                        +   Code:ce8001M386B8G70BO0-YH94   0000-23BE2621;
                        +   Type:47;   Size:64   GB;
                MEM#03A   Status:Normal;
                        +   Code:ce8001M386B8G70BO0-YH94   0000-2151EFE0;
                        +   Type:47;   Size:64   GB;
                MEM#10A   Status:Normal;
                        +   Code:ce8001M386B8G70BO0-YH94   0000-2151EF7E;
Appendix A Troubleshooting