                PSU#0   Status:Normal;   Ver:303443h;   Serial:MD12190452   ;
                        +   FRU-Part-Number:CA01022-0761   /   ;
                        +   Power_Status:ON;   AC:200   V;   Type:   A   ;
                PSU#1   Status:Normal;   Ver:303443h;   Serial:MD12190454   ;
                        +   FRU-Part-Number:CA01022-0761   /   ;
                        +   Power_Status:ON;   AC:200   V;   Type:   A   ;
                FANU#0   Status:Normal;
                FANU#1   Status:Normal;
                FANU#2   Status:Normal;
                FANU#3   Status:Normal;
                FANU#4   Status:Normal;
        BB#01   Status:Normal;   Role:Standby   Ver:0101h;   Serial:7867000297 ;  
                                                                                                  * Chassis serial number
                +   FRU-Part-Number:CA20393-B50X   A2   ;
                +   Power_Supply_System:Single;
                +   Memory_Size:256   GB;
                                            Omitted       
    XBBOX#80   Status:Normal;   Role:Master   Ver:0101h;   Serial:7867000297 ;  
                                                      * Chassis serial number
                      +   FRU-Part-Number:CA07361-D011   A0   /NOT-FIXD-01   ;
                      +   Power_Supply_System:Single;
                      XBU#0   Status:Normal;   Serial:PP0629L068
                              +   FRU-Part-Number:CA20393-B50X   A2   ;
                      XSCFU   Status:Normal;   Ver:0101h;   Serial:7867000262   ;
                              +   FRU-Part-Number:CA20393-B56X   A0
                      XBBPU   Status:Normal;   Serial:PP0629L068
                              +   FRU-Part-Number:CA20393-B50X   A2   ;
                      XSCFIFU   Status:Normal;   Ver:0101h;   Serial:PP12040198   ;
                              +   FRU-Part-Number:CA20365-B52X   001AA/NOT-FIXD-01   ;   Type:   A   ;
                      OPNL   Status:Normal;   Serial:PP0629L068
                              +   FRU-Part-Number:CA20393-B50X   A2   ;
                      PSU#0   Status:Normal;   Ver:0201   Serial:0000000-ASTECB18   ;
                              +   FRU-Part-Number:CF00300-1898   0002   /300-1898-00-02;
                              +   Power_Status:ON;   AC:200   V;
showhardconf -u command
Use the showhardconf command with the -u option to display the quantity of each
type of mounted field replaceable unit.
The CPU modules are displayed with the operating frequency, and the memory units
are displayed with the capacity per memory. If the option is omitted, the command
displays the current configuration information, status information, and physical
partition (PPAR) information for each field replaceable unit.
Example: SPARC M10-1 display example
XSCF>   showhardconf -u
SPARC   M10-1;   Memory_Size:1024   GB;  
+-----------------------------------+------------+
|   FRU                                                               |   Quantity       |
+-----------------------------------+------------+
|   MBU                                                               |         1               |
|           Type:B                                                 |     (   1)             |